Demystifying IECEx and ATEX Marking String - Key Differences and What They Mean Header-DESKTOP-75JNLC0
  • 2024-06-13
  • Frida Kutasi

Demystifying IECEx and ATEX Marking String: Key Differences and What They Mean

IECEx and ATEX marking again? Why are you writing about this topic? I am easily able to find multiple similar-themed articles or blog posts, which ones already detail the information…

Yes, you are right! So, if you are able to understand this example you can continue your browsing for some more informative content (We would appreciate it if you check our other blog posts or even our website.).

Let’s see, do you know what this means?

Ex tb [ib Db] IIIC T135°C Db

If you feel a little bit confused, or you think you need to check the standard to decipher the meaning of it, just keep reading. I will help demystify the meaning of it or even a little bit more! Come with me Dear Reader into the coded world of IECEx and ATEX markings in EN IEC 60079-0 standard.

This explanation was written based on the order of use of the string’s characteristics.

Difference Between IECEx and ATEX Marking

There is a very simple and easily identifiable difference. The IECEx marking string is always the shorter one.

  • Does not contain Ex icon and
  • has fewer characters (and lacks CE mark).
Difference between IECEx and ATEX marking

Particularities of ATEX Marking String

Particularities of ATEX marking string - ATEX

Apart from the Ex icon and the CE marking, the ATEX-specific part of the string gives us information about the following:

  • 1st Equipment Group (“II”)

  • 2nd Equipment Category (“2D”)

Between the two categories always keep 1 space!

Equipment Group

Apart from the Ex icon and the CE marking, the ATEX-specific part of the string gives us information about the following:

  • 1st Equipment Group (“II”)

  • 2nd Equipment Category (“2D”)

Between the two categories always keep 1 space!

Particularities of ATEX marking string

Equipment Category

Let’s crack the code on Equipment Category within explosion-proof equipment markings. Think of it as a nested category with a two-digit code: a letter and a number.

In Mines:

  • The code starts with the letter “M” followed by a number (1 or 2).
  • 1: Equipment designed for mines and must function even in an explosive atmosphere (tough stuff!).
  • 2: Equipment for mines, but meant to be de-energized when there’s a risk of explosion (safety first!).

For Gas and Dust:

  • The code flips the order, starting with a number (1, 2, or 3) followed by “G” for gas or “D” for dust.
  • The number gets trickier here:
    • 1: Non-mining, Zone0/20 (most hazardous)
    • 2: Non-mining, Zone1/21
    • 3: Non-mining, Zone2/22 (least hazardous)

While memorizing the exact code might be a challenge, the key takeaway is simple: lower numbers signify a higher level of explosion risk.

Explosion Protection

Explosion Protection

This will be a brief chapter. In every string (IECEx and ATEX too) “Ex” means: the product is explosion protected. At IECEx this is the first part of the marking string. At ATEX it follows the special ATEX characters.

Type of Protection and Level of Protection

Type of Protection and Level of Protection

So already, the marking string of this product is defined as explosion-protected (“Ex”). Subsequently, the type of protection method employed to ensure the product’s safety is indicated. Almost 10 different Types of Protection can be distinguished. Some of their names harmonize with the indicated letter of it. Like “i” intrinsic safe Type of Protection. But as usual, there are more differences. Check the picture for a better understanding.

The Level of Protection is derived from these. It is from 2 pcs letter:

  • the first is the Type of Protection (“d”) and

  • the second is for the hazardous environment where is allowed to place the product (“b”).

This environment indication here is based on letters not numbers as ATEX Equipment Category:

  • “a” for Zone0/20,
  • “b” for Zone1/21, and
  • “c” for Zone2/22

Those letters need to be the same here (in most cases) and at the Equipment Protection Level (EPL)!

Type of Protection

Gas Group and Dust Group Marking

Gas Group and Dust Group

Now we already know that the product is explosion-protected, how protected, and where can be found. Here comes the dust and gas protection specification. These string elements show specific characteristics in every variant.

  • Group II stands for gas atmosphere.
  • Group III for dust atmosphere.

In this classification, it is noteworthy that the gas and dust area “A” is less prone to ignition compared to the gas and dust areas “B” and “C”, and “C” being the most prone to ignition.

Gas and Dust Group marking

Temperature Classes

Temperature Classes

For Group I electrical equipment, the maximum surface temperature shall not exceed 150°C on any surface where coal dust may be present. If the equipment is protected from the coal dust (e.g. inside a dust-protected enclosure), then the maximum allowed surface temperature is 450°C. The temperature is not classified or otherwise indicated in the marking string.

In the IECEx and ATEX marking strings for Group II equipment, there are 6 different Temperature Classes between 450°C and 85°C for the maximum surface temperature. These values are to be assessed in the context of the ambient temperature where the product is to be used. Example: Ex ib IIC T4 Gb.

The interesting thing about the topic is that the larger the Temperature Class’s number, the smaller the value of the maximum surface temperature.

In Group III equipment, the maximum surface temperature that may appear on the equipment, must be indicated in the marking string. Example: Ex tb IIIC T135°C Db.

Equipment Protection Level

Equipment Protection Level

After this amount of information, I think you can already identify the last part of an IECEx or ATEX marking string. It contains 2 letters:

  • the first is a capital letter in connection with Equipment Group (M-mine, G-gas, D-dust)
  • the second indicates the Level of Protection (a-Zone0/20, b-Zone1/21, c-Zone2/22)

Ever wondered what those 2 letters are at the end of the string? Why do they repeat themselves? Let’s focus on the seemingly redundant last two characters (Gas Group: Ga, Gb, Gc, and Dust Group: Da, Db, Dc).
These characters combine info already given earlier in the code. But they’re not always useless! In some cases, they provide a bit extra:

  • Alternate Marking: The code can specify a broader range of suitability. For example, “Ex ia IIC T4 Gb” indicates the equipment is certified for Zone0 („a”) but must installed in Zone1 („b”).
  • Emphasis: Manufacturers might use the full code leaving no room for misinterpretation.
  • Future-proofing: Standards evolve, and these characters might hold additional info in future revisions.

While the first part of the code often does the trick, these last characters can offer hidden value. Remember, always refer to the equipment documentation and relevant standards for the full picture.

Special Characteristics of IECEx and ATEX Marking Strings

We have arrived at the end of the “simple” marking string explanation. For deeper understanding let’s see some unique usage cases.

  • Ex tb [ib Db] IIIC T135°C Db: as our first example. The square bracket content indicates that inside the dust-protected enclosure (“tb”) can connect intrinsic safe equipment from Zone1 (“ib”).
  • Ex ia/tb IIIC T85°C Da/Db: Boundary wall installed equipment. Need to add a slash between the Level of Protection and the Equipment Protection Levels.

What does this mean? Test your knowledge about marking

Phew, that was a lot to unpack! Thanks for reading.

I hope now you feel more confident about IECEx and ATEX markings. I am presenting you with two cards. Try to figure out their meanings. After that, you can flip the card and check the result. Do not cheat! You can do it!

II 2D Ex tb ib IIC T85°C Db

It’s a WRONG one. Let’s see why:

  • Ex icon missing, because the string looks like ATEX kind.
  • The Level of protection (“tb” and “ib”) needs to be in alphabetic order.
  • For the dust environment certification string the Equipment Grouping (IIC) needs to be IIIC.

Ex ib IIC T4 Gb

  • It is an IECEx marking.
  • The Type of Protection of the product is “i” intrinsic safety with a second letter indicating the Level of Protection “ib”. This means intrinsic safety for Zone1
  • “IIC” for Gas group and the most ignitable type gas group
  • “T4” is the Temperature Class and the maximum surface temperature +135°C
  • The one: “Gb” for Equipment Protection Level. “G” as gas environment inside “b” as Zone1

Now you’re an expert on IECEx and ATEX markings! Time to share your knowledge.

If you need a handy help, you can download the following picture.

Guide IECEx and ATEX Marking String

Tags:

ATEXCertificationExIECExIntrinsic safetyMarking
Previous Post
Next Post

ADOTT Solutions Services

  • Intrinsic Safety and Intrinsically Safe Design
  • Industrial Design & Strategy
  • Mechanical & Electronics Engineering
  • Product Manufacturing & Supply Chain Services

Tags

ATEX Battery Certificate Certification Design Design Criteria Development DFM Energy Storage Engineering Services Ex Fuell-cell Future graduated H2 Hardware design Hazardous Environment Hydrogen Hydrogen Technology Engineering IEC 60079-11:2023 IECEx Industrial design Industrial Robots innovation Intrinsic safety Lithium Ceramic Battery Manufacturing Marking Mechanical design Mechanical engineer Outsource Product Production SAFE Safety Services Standard Supply Chain ZONES

Recent Post

  • crysa
    2025-03-10
    Complexity of IEC 60079 Standards Universe – A Comprehensive Overview
  • crysa
    2025-01-24
    Straight from the Source: Q&A with our in-house IEC Delegate About the Evolving Standards

 Let’s Build Something Great Together

Contact us today to discuss your project or get tailored solutions from our team.

ADOTT-Solutins-brand-logo-color

ADOTT SOLUTIONS

Siklósi way 2
7622 Pécs
HUNGARY
VAT ID Nr. : HU23087718

szechenyi-2020

© Copyright 2024. All Rights Reserved by ADOTT Solutions.

Menu
  • Privacy Policy
  • Cookie Policy (EU)
ADOTT-Solutins-brand-logo-color
Manage Cookie Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
View preferences
{title} {title} {title}

Please enable JavaScript in your browser to complete this form.
Loading