ADOTT Solutions
ADOTT Solutions
  • Services
    • Ex Intrinsic Safety
    • Ex Certification & Support
    • Electronics Engineering
    • Mechanical Engineering
    • Industrial Design & Strategy
    • Product Manufacturing & Supply Chain Services
  • Ex Battery
  • Portfolio
  • Resources
    • IEC 60079-11:2023 Comprehensive Guide
    • IEC 60079 Checklist
  • Ex Products
    • Ex Safe-Separator Battery
    • Intrinsically Safe – Power Protection
    • Intrinsically Safe – Ethernet Protection
    • Intrinsically Safe – Boost Protection
    • BLUEDOTT ZONE1 Ex Battery
    • X-Ray Shielding Encapsulation Resin
  • About Us
  • Blog
  • Career
IEC 60079-11:2023 Checklist
  • 2024-11-21
  • Frida Kutasi

IEC 60079-11:2023 Compliance Checklist

Navigating the complexities of IEC 60079-11:2023 can be daunting, especially with the recent updates in Edition 7. A well-structured checklist is a valuable tool to ensure compliance and streamline the certification process. This blog post will guide you through the importance of checklists, common pitfalls, and key considerations for a successful IEC 60079-11:2023 compliance journey.

What is a Checklist?

Let’s start with the basics and build our topic step by step. A checklist is a list of items, tasks, or questions that you can use to ensure that nothing is forgotten or overlooked. It’s a helpful tool for staying organized, completing tasks efficiently, and making sure you have everything you need.

These explosion-proof related standards are detailed and complex. IEC 60079-11:2023 is no different. This is the place where a checklist can come to your help. A good checklist for product design or manufacturing is the essence of the standards. In the context of IEC 60079-11:2023, a checklist is a document that outlines the Edition 7 standard, the table of contents.

Why Is a Checklist Important and Useful For IEC 60079-11:2023 Compliance?

The preparation of your “Ex i” product’s IECEx and ATEX certification can be overwhelming if you do not use a checklist. Too many checkpoints and you need to demonstrate that you comply with them. That is only possible if you do it in a structured way. With a checklist of a standard. You can list every document to the requirement points and you will able to create a list of documents that need to be submitted to the certification process.

IEC 60079-11:2023 Useful Checklist

Because the new Edition 7 IEC 60079-11:2023 contains multiple changes major and minor too, that would be best if you start filling out the checklist after your product’s specification is finalized. You can review your requirements with the standard. With this, you will able the consider that you should modify the specification of your product or change the level of protection of the product. Of course, you can modify both of them under or after designing your product, but in that case,

  • you will lose time,
  • resources, and
  • money.

So, for your effective work, the correct use of the checklist is valued.

Common Mistakes in Filling Out an IEC 60079-11:2023 Checklist

While checklists are a valuable tool, it’s important to avoid common mistakes when filling them out. Some of the most common mistakes include:

  • Not up-to-date the checklist that you use: You already had a checklist for IEC 60079-11? Be careful, because the new Edition 7 contains major structural changes! Before you start to fill your checklist make sure that is the latest version.

  • Filling out the checklist without the IEC 60079-11:2023 standard: Do you think you remember what this chapter is about? You need to make sure. Always keep open the standard while you filling the checklist.

  • Lack of document reference: Failing to provide complete and accurate information can lead to incorrect assessments and potential safety risks. The best way to avoid this is to fill out the exact document (like 123-03 User Manual) or a document type (like User Manual) in the checklist. This way you can easily implement the required data in your product documentation.

Key Points to Consider in an IEC 60079-11:2023 Checklist

When creating or using an IEC 60079-11:2023 checklist, it’s important to focus on the following key points:

  • Filling the checklist: During your product design. To make sure that your product meets all the requirements.

  • Product classification: Ensure that the product is correctly classified according to its intended use and the hazardous area it will be installed. The best if you write the full (target) marking string on the top of your checklist and fill it in accordance with this marking string.

  • Design and construction: In IEC 60079-11:2023 implemented major changes at cells and batteries. If your product contains this be cautious. Make sure your design is compatible with this requirement and that you provide enough samples for testing.

  • Component selection: Ensure that all components used in the product (especially electrical components) are suitable for use in connection with IEC 60079-11:2023 requirements.

  • Marking and labeling: One of the crucial points of a product from conformity point of view. The clearest way of preparing the marking of the product is you fill first checklist. Then summarize the required content of marking and after that try to place it on the product.

  • Testing and verification: Ensure that the product or its components (Like populated PCB) has been adequately prepared for Ex related testing and inspected to verify its compliance. So, you cannot just skip the Testing chapters of the checklist.

IEC 60079-11:2023 Checklist Key points

Conclusion

By effectively utilizing an IEC 60079-11:2023 checklist, you can significantly enhance the safety and reliability of your electrical equipment and systems in hazardous areas. Remember to pay close attention to detail, seek clarification when needed, and stay updated with the latest standards and regulations.

To assist you further, we have created a downloadable checklist for IEC 60079-11:2023.

[DOWNLOAD HERE]

If you encounter any challenges with the checklist, standard interpretation, or design questions, our experienced team is ready to provide expert guidance and support. Feel free to reach out to us with your inquiries.

Tags:

ExIEC 60079-11:2023IECExIntrinsic safetyStandard
Previous Post
Next Post

ADOTT Solutions Services

  • Intrinsic Safety and Intrinsically Safe Design
  • Industrial Design & Strategy
  • Mechanical & Electronics Engineering
  • Product Manufacturing & Supply Chain Services

Tags

ATEX Battery Certificate Certification Design Design Criteria Development DFM Energy Storage Engineering Services Ex Fuell-cell Future graduated H2 Hardware design Hazardous Environment Hydrogen Hydrogen Technology Engineering IEC 60079-11:2023 IECEx Industrial design Industrial Robots innovation Intrinsic safety Lithium Ceramic Battery Manufacturing Marking Mechanical design Mechanical engineer Outsource Product Production SAFE Safety Services Standard Supply Chain ZONES

Recent Post

  • crysa
    2025-03-10
    Complexity of IEC 60079 Standards Universe – A Comprehensive Overview
  • crysa
    2025-01-24
    Straight from the Source: Q&A with our in-house IEC Delegate About the Evolving Standards

 Let’s Build Something Great Together

Contact us today to discuss your project or get tailored solutions from our team.

ADOTT-Solutins-brand-logo-color

ADOTT SOLUTIONS

Siklósi way 2
7622 Pécs
HUNGARY
VAT ID Nr. : HU23087718

szechenyi-2020

© Copyright 2024. All Rights Reserved by ADOTT Solutions.

Menu
  • Privacy Policy
  • Cookie Policy (EU)
ADOTT-Solutins-brand-logo-color
Manage Cookie Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
View preferences
{title} {title} {title}

Please enable JavaScript in your browser to complete this form.
Loading